www.Sweetfilter.com
General
The idea behind the PEC Sweetfilter is
to provide a localized source of odor
control for cold air roof vents. High efficiency
activated carbon and zeolite mix
canister type absorbers are mounted on
the roof vent. Foul air passes through
the absorber and odors are removed by
the activated carbon and zeolite mix.
Operational
Features
- Activated Zeo-Carbon Filter continuously
cleans circulation air.
- Canister easily slides onto roof
vent.
- Design allows capture of specific gas molecules such as: Ammonia, aldehydes, carbon dioxide, carbon monoxide, ethylene, hydrogen sulfide, ketones, and mercaptans among others.
- REGENERATION
Unlike other products, Zeo-Carbon has the unique ability of regeneration. Operation takes advantage of exposure to natural fresh air flows, building heat, and sunlight. A few hours of normal building inactivity and its ready to go to work again.
Description
- Air intake grille (A) = 4.25 inches I.D.
- Media canister (B)= 4.6 inches O. D.
- Roof vent pipe coupling connection (C) = 4.50 inches I.D.(invert allows for 2" insert of existing vent stack)
- Overall length (D) =6.0 inches
- Media fill (1lb), ship weight 3.5 lbs
Safety Tips
- UNIT zeo-carbon medias operates near 100% humidity (wet). During long periods of inactive use, no water flow, or inclement weather allow 24 hours for auto-regeneration to occur (see freezing weather recommendations).
- DO NOT store or expose unit to any
source of direct heat such as radiators
or heat vents.
- DO NOT expose unit to any
inflammable liquids/gases as unit will
rapidly absorb them diminishing unit
capacity
- DO NOT store units in an
unventilated area. Stored units will
produce strong odors during
storage.
- The unit is most effective
when the
building/vent temperature is above 60F
and below 95F.
- If the inside building temperature is allowed to drop
below 60F ice may form on any vent stack,
above 95F odor absorbtion is reduced.
Maintenance
- Annually inspect and clean the air
intake grille.
- Visually inspect the units after
inclement or freezing weather to insure proper
operation (ie: not buried under snow pack, leaves, etc.).


www.Sweetfilter.com
Website
PEC Sweetfilter®
Instruction Manual (page 2 of 2)
Installation
- Run water down all plumbing drains regularly to insure water seals are full and working. Water seals dry out quickly in unused floor drains and allow gas to vent indoors. We recommend that infrequently used drains recieve a quarterly application of our www.aerotrap.com liquid. Aerotrap liquid lasts in drain traps for 3-6 months stopping odor from venting inside and killing odor producing bacteria found in drain traps and piping.
- Remove 1-3" optional reducer bushing from ("C" Roof vent pipe coupling connection) and discard if vent stack is larger than 3".


- Remove bottom screws from "C" counter-clockwise (1-5 screws depending on model), place unit on vent
stack,
and replace screws clockwise until unit is secure.
- Some Zeo-Carbon dust loss during
transportation and installation is normal.
Troubleshooting
- Unit does not work....inspect and
clean the air intake grille.
- Capacity
diminished....short term return of odors is due to overload of filter and online recovery time is needed. Long term, (more than two weeks) return of odors requires larger units and/or recharge of the
activated Zeo-Carbon. Click here to purchase zeo-carbon refill bag... (requires removal of unit intake grill for access to spent zeo-carbon).
Limited
Warranty
- PEC warrants each product and any
parts thereof sold by it to be free from
defects in materials and workmanship
under normal use and service for TWELVE
(12) MONTHS from the date of delivery to
the original purchaser at retail subject
to the following terms and conditions:
- What is covered: Product or parts
thereof which are defective in
workmanship.
- What is NOT covered: This warranty
does not extend to any defect due to the
negligence of others: failure to
install,
operate, or maintain unit in accordance
with installation instructions
(operating and installation instructions
are supplied with each unit):
unreasonable use, accidents, alteration,
use of unauthorized or non-standardized
PEC parts and accesories; air flow
malfunction due to plugged grille or
canister, i.e., as resulting from large
power outages, inclement weather, freezing, or
other acts of god.
- Who is covered: The original
purchaser at retail.
- What we will do: PEC will repair or
replace, at its option, all defective
parts free of charge that are by this
limited warranty on a carry-in basis, to
your nearest authorized dealer or
distributor.
- What you must do for warranty
service: You must return the defective
product or part to any authorized dealer
or distributor of PEC products with this
limited warranty and a copy of your
documents evidencing the date of the
products delivery. If service is not
available locally you must contact our customer
relations department for a RMA# and instructions on shipment of used units at:
PEC
1520 N. 6th
Street
Springfield, IL.
62702
tel. (888) 261-4726.....toll free voice mail/fax (866)
422-0018
CAUTION !!! DO NOT RETURN USED UNITS FOR REGENERATION OR FOR ANY REASON BY USPS MAIL! NO SHIPMENTS WILL BE ACCEPTED WITHOUT A RMA#!!!
THE FOREGOING EXPRESSES ALL OF PEC'S
OBLIGATIONS AND LIABILITIES WITH RESPECT
TO THE QUALITY OF PRODUCT FURNISHED BY
IT. ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ARE DISCLAIMED. PEC
SHALL NOT BE LIABLE FOR THE LOSS OF ANY
PRODUCT, INCONVENIENCE, LOSS OR ANY
OTHER DAMAGES, DIRECT OR CONSEQUENTIAL
ARISING OUT OF, THE USE OF, OR INABILTY
TO USE, THE PRODUCT OR DAMAGES RESULTING
FROM OR ATTRIBUTABLE TO DEFECTS IN THE
PRODUCT.
Go to...
http://www.Sweetfilter.com